Olympus BHM (BH-2) Series Metallurgical Microscopes catalogue: December 1982: 8.90 MB: Olympus LBM Objectives Prices and Specifications: January 1993: 943 KB: Olympus BHM (BH) Metallurgical System Microscope instruction manual: November 1980: 1.22 MB: Olympus BHMJ & BHMJ-N Metallurgical Microscopes instruction manual: March 1980: 4.70 MB. Taken from Andrew Zonenberg's BHM unless otherwise stated. Attaches to microscope frame with four M6x1.0 screws, 15 mm long, in a 2x2 hole pattern. Screw heads are 9.9 mm OD. OLYMPUS MICROSCOPE, REFLECTED LIGHT - BRIGHTFIELD & DARKFIELD. Reflected Light Microscope with BH2-UMA Vertical Illuminator. In addition to this Olympus BHM/BH2-UMA, Capovani Brothers Inc stocks a wide range of used upright microscopes. Typical manufacturers include American Optical, Bausch & Lomb, Leica, Nikon, Olympus. Olympus-BHMMicroscope-InstructionManual.pdf (file size: 4.42 MB, MIME type: application/pdf) Summary Instruction user Manual for Olympus BMH. microscopes, scanned at Nanofab.
- 1Part list
- 4Measurements
Model
TODO: add standard metallurgical
Image | Name | Description | Notes |
---|---|---|---|
Source: [BH microscope, cover] [[BHA] | Bottom illumination, removable nosepiece | ||
BHB | Bottom illumination, fixed nosepiece | ||
BHC | Bottom illumination, fixed nosepiece, integrated light source | ||
BHMJ-02 | Epi-illumination, sliding stanmd, BF, monocular | ||
BHMJ-22 | Epi-illumination, sliding stanmd, BF, binocular | ||
Source: [instruction BHMJ/-N, 3] [[BHMJ-42] | Epi-illumination, sliding stanmd, BF, trinocular | ||
BHMJ-02-N | Epi-illumination, sliding stanmd, BF/DF, monocular | ||
BHMJ-22-N | Epi-illumination, sliding stanmd, BF/DF, binocular | ||
BHMJ-42-N | Epi-illumination, sliding stanmd, BF/DF, trinocular |
Objective
M is BF only. Neo are BF/DF. All are M25 threaded
Image | Part # | Type | Description | Notes |
---|---|---|---|---|
M5X | Objective | 5x | ||
M10X | Objective | 10x | ||
M20X | Objective | 20x | ||
M40X | Objective | 40x | ||
Neo5X | Objective | 5x | ||
Neo10X | Objective | 10x | ||
Neo20X | Objective | 20x | ||
Neo40X | Objective | 40x | ||
BH-RE | Nosepiece | Quintuple | ||
BH-RE | Nosepiece | |||
BH-NRE | Nosepiece |
Illuminator
Image | Part # | Type | Description | Notes |
---|---|---|---|---|
BH-MA | Illuminator (vertical) | Brightfield | ||
BH-RLA | Illuminator (vertical) | Brightfield and darkfield | ||
Source: [BH microscope, 9] [[BH-LH] | Lamphouse | Tungsten, 30W | Pre-centered | |
BH-LHM | Lamphouse | Tungsten | ||
Source: [BH microscope, 9] [[BH-LSH] | Lamphouse | Halogen 100W | Centerable | |
Source: [BH microscope, 9] [[BH-LH] | Lamphouse | |||
Source: [BH microscope, 9] [[LS30] | Bulb | 6V, 30W tungsten | ||
Source: [BH microscope, 9] [[LS15] | Bulb | 6V, 15W tungsten | ||
FK5X | Eyepiece, photo | 5x | ||
TF | Power supply | Transformer | voltage range? | |
45C | Filter | for what? | ||
Source: [BH microscope, 9] [[jc12v 100W] | Bulb | Halogen |
Observation tube
Image | Part # | Type | Description | Notes |
---|---|---|---|---|
CH-M045 | Observation tube | Monocular | ||
Source: [BH microscope, 11] [[BH-SWTR] | Observation tube | Binocular w/ photo? | ||
Source: [BH microscope, 11] [[BH-BI30] | Observation tube | Binocular, 30 degree | ||
Source: [BH microscope, 11] [[BH-BI45] | Observation tube | Binocular, 45 degree | ||
Source: [BH microscope, 11] [[BH-TR30] | Observation tube | Binocular, 30 degree (w/ photo) | ||
Source: [BH microscope, 11] [[BH-TR45] | Observation tube | Binocular, 45 degree (w/ photo) | ||
BiWF10X | Eyepiece | HEP, paired | ||
Source: [BH microscope, 15] [[EMM-VI] | ||||
Source: [BH microscope, 15] [[PM-10-35A] | ||||
Source: [BH microscope, 15] [[PM-10-35L2A] | ||||
Source: [BH microscope, 15] [[PM-10-35M] | ||||
Source: [BH microscope, 15] [[PM-6] |
Misc
Image | Part # | Type | Description | Notes |
---|---|---|---|---|
[[BH-RE] | Nosepiece | Quintuple | Neo objectives (M25) | |
Source: [BH microscope, 9] [[BHA-F] | Stand | Bottom illumination, removable nosepiece | ||
Source: [BH microscope, 9] [[BHB-F] | Stand | Bottom illumination, fixed nosepiece | ||
Source: [BH microscope, 9] [[BHC-F] | Stand | Bottom illumination, fixed nosepiece, integrated light | Lowest cost? | |
Source: [BH microscope, 13] [[BH-SV] | Stage | |||
Source: [BH microscope, 13] [[BH-CD] | Condenser | Abbe | ||
Source: [BH microscope, 13] [[BH-AAC] | Condenser | Ach/Apla | ||
BHMJ-ST, BHMJ-F | Body/base | |||
FK3.3X | Photo eyepiece | |||
32.5C | Blue filter | |||
Source: [BH microscope, 11] [[AH-CA] | ||||
Source: [BH microscope, 11] [[AH-FA] | ||||
Source: [BH microscope, 13] [[BH-DCD] | ||||
Source: [BH microscope, 13] [[BH-DCW] | ||||
Source: [BH microscope, 13] [[BH-PC] | ||||
Source: [BH microscope, 13] [[BH-SH] | ||||
Source: [BH microscope, 13] [[BH-SWC] |
Olympus Bhmjl Microscope
Above: probably a BHA. Source: [BH microscope, cover]
What Does An Olympus Bhm-man Analyzer Do In 2
Source: [BH microscope, 18]
NOTE: -1, -2, etc are my notation for the color columns in [BH microscope, 18]
Part # | Type | Description | BHA-1 | BHA-2 | BHA-3 | BHA-4 | BHB-1 | BHB-2 | BHB-3 | BHB-4 | BHC-1 | BHC-2 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
BHA-F | Stand | Y | Y | Y | Y | |||||||
BHB-F | Stand | Y | Y | Y | Y | |||||||
BHC-F | Stand | Y | Y | |||||||||
BH-RE | Nosepiece | Quintuple | Y | Y | Y | Y | ||||||
BH-LH | Lamphouse | Y | Y | Y | Y | Y | Y | Y | Y | |||
LS30 | Bulb | 6V, 30W | Y | Y | Y | Y | Y | Y | Y | Y | ||
LS15 | Bulb | 6V, 15W | Y | Y | ||||||||
BH-BI45 | Observation tube | 45 deg binocular | Y | Y | Y | Y | Y | |||||
BH-TR45 | Observation tube | 45 deg trinocular | Y | Y | Y | Y | Y | |||||
BH-SV | Stage | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | |
BH-CD | Condenser | Abbe | Y | Y | Y | Y | Y | Y | Y | Y | ||
BH-AAC | Condenser | Ach/Apla | Y | Y | ||||||||
Objective | Achromat 4x, 10x, S-40x (spring), S-100x (spring, oil) set | Y | Y | Y | Y | Y | Y | |||||
Objective | Plan achromat 4x, 10x, 40x (spring), 100x (spring, oil) set | Y | Y | Y | Y | |||||||
Objective | Plan achromat 20x (spring) | Y | Y | |||||||||
BiWF10X | Eyepiece | HEP, paired | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
FK5X | Eyepiece, photo | 5x | Y | Y | Y | Y | Y | |||||
45C | Filter | for what? | ||||||||||
Bulb | Spare bulb (2x) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | |
Fuse | Spare fuse (2x) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | |
Oil | Immersion oil | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | |
Cover | Vintyl dust cover | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Above: A BHMJ, probably a BHMJ-42. Source: [instruction BHMJ/-N, 3]
Source: [instruction BHMJ/-N, 2]
-N adds darkfield
Part # | Type | Description | BHMJ-02 | BHMJ-22 | BHMJ-42 | BHMJ-02-N | BHMJ-22-N | BHMJ-42-N |
---|---|---|---|---|---|---|---|---|
BHMJ-ST, BHMJ-F | Body/base | Y | Y | Y | Y | Y | Y | |
BH-RE | Nosepiece | Y | Y | Y | ||||
BH-NRE | Nosepiece | Y | Y | Y | ||||
BH-MA | Illuminator (vertical) | Brightfield | Y | Y | Y | |||
BH-RLA | Illuminator (vertical) | Brightfield and darkfield | Y | Y | Y | |||
CH-M045 | Observation tube | Monocular | Y | Y | ||||
BH-BI45 | Observation tube | Monocular | Y | Y | ||||
BH-TR45 | Observation tube | Binocular (w/ photo) | Y | Y | ||||
BH-LHM | Lamphouse | Tungsten | Y | Y | Y | Y | Y | Y |
LS15 | Bulb | 15W tungsten | Y | Y | Y | Y | Y | Y |
TF | Power supply | Transformer | Y | Y | Y | Y | Y | Y |
M5X M10X M20X M40X | Objective | Set | Y | Y | Y | |||
Neo5X Neo10X Neo20X Neo40x | Objective | Set | Y | Y | Y | |||
High eyepoint BiWF10X,paired eyepiece | Y | Y | Y | Y | ||||
High eyepoint WF10X eyepiece | Y | Y | ||||||
FK3.3X | Photo eyepiece | Y | Y | |||||
Stage plate | Y | Y | Y | Y | Y | Y | ||
Stage clips | Y | Y | Y | Y | Y | Y | ||
Eyepiece caps | Y | Y | Y | Y | ||||
32.5C | Blue filter | Y | Y | Y | Y | Y | Y | |
Vinyl dust cover | Y | Y | Y | Y | Y | Y |
Taken from Andrew Zonenberg's BHM unless otherwise stated.
Base plate
Attaches to microscope frame with four M6x1.0 screws, 15 mm long, in a 2x2 hole pattern. Screw heads are 9.9 mm OD.
Base plate has 6.7mm clearance holes, scope body is tapped.
Approx 135 mm front-to-back from center of microscope frame to sample.
- Olympus Series BH System Microscope [BH microscope]: [1]
- Olympus metallurgical microscopes instruction manual, models BHMJ & BHMJ-N [instruction BHMJ/-N]: [2]
Summary
Olympus Bhm Nosepiece
Instruction user Manual for Olympus BMH* microscopes, scanned at Nanofab
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Dimensions | User | Comment | |
---|---|---|---|---|
current | 11:50, 3 December 2019 | (4.42 MB) | John d(talk | contribs) | Instruction user Manual for Olympus BMH* microscopes, scanned at Nanofab |
- You cannot overwrite this file.